Go to https://itkpd.unicornuniversity.net/ and log in
Click “My Components” on the menu on the right
Click on the blue “Register” button
Fill out the details of the bus tape. The Component Type is ‘Bus Tape’. The ATLAS Serial Number must be set manually following the rules described in the box below.
At the moment you are asked to enter a “Bus Tape Prototype” and “Petal Tape Pre-Production”. These are Batch Types. If you wish to log which batch a tape comes from, you can enter something here. I just entered ‘NA’ for these.
Click “Register”
After registering a tape, you can set the stage, which is initially set to ‘Bare’, but can be changed to ‘Co-cured’, and ‘Tape on stave/petal’.
To upload a test data file, click on the ‘+’ next to ‘Attachments’.
To create and enter the key results of an electrical or stave test, click on the ‘+’ next to Tests