Tests Per Stage

stage code: BARE

test_name test_code test_order
Bus Tape Electrical Test BTELECTRICAL 0
Bus Tape Metrology Test BTMETROLOGY 1
Bus Tape LBL Metrology Test BTMETROLOGY_LBL 2
Bus Tape Stretch Test Petal BTSTRETCHP 3
Bus Tape Weight Test BTWEIGHT 5
Bus Tape Visual Inspection BTVISUAL 6

stage code: COCURED

test_name test_code test_order
Bus Tape Electrical Test BTELECTRICAL 0
Bus Tape Metrology Test BTMETROLOGY 1
Bus Tape LBL Metrology Test BTMETROLOGY_LBL 2
Bus Tape Stretch Test Petal BTSTRETCHP 3
Bus Tape Weight Test BTWEIGHT 5
Bus Tape Visual Inspection BTVISUAL 6
Bus Tape Co-Curing BTCOCURING 7
Bus Tape Thickness Test BTTHICKNESS 8
Bus Tape Bond Pull Test BTBOND 9

stage code: RECEPTION

test_name test_code test_order
Thickness check Face Sheet THICKNESS_CHECK 1

stage code: COMPLETED

test_name test_code test_order
Bus Tape Electrical Test BTELECTRICAL 0
Bus Tape Metrology Test BTMETROLOGY 1
Bus Tape LBL Metrology Test BTMETROLOGY_LBL 2
Bus Tape Stretch Test Petal BTSTRETCHP 3

Test Details

test code: BTELECTRICAL

stages: BARE, COCURED, COMPLETED

properties

name code description dataType valueType required
Test results file FILE The zip file containing the full test results string single False

parameters

name code description dataType valueType required
Shorts or HV failure SHORTS_OR_HV_FAILURE Number of nets flagged with shorts or HV failure integer single True
Red Flags RED_FLAGS Number of nets flagged RED in TapeTestLog as at least one measured resistance more than 2 Ohm above expected value integer single True
Amber Flags AMBER_FLAGS Number of nets flagged AMBER in TapeTestLog as a measured resistance was too high the first time, but passed when test was repeated. integer single True

test code: BTMETROLOGY

stages: BARE, COCURED, COMPLETED

properties

name code description dataType valueType required
Test results file FILE Zip file containing the full test results string single False

parameters

name code description dataType valueType required
dx/x DXVSX Fractional increase in length float single True
Max dy MAXDY The maximum deviation of fiducial points in the y direction (perpendicular to the tape length) float single True

test code: BTMETROLOGY_LBL

stages: BARE, COCURED, COMPLETED

properties

name code description dataType valueType required
File name FILE Test data file name string single False

parameters

name code description dataType valueType required
Average X AV_X Average X float single True
Max Y MAX_Y Max Y float single True

test code: BTSTRETCHP

stages: BARE, COCURED, COMPLETED

properties

name code description dataType valueType required
Test results file FILE Zip file containing the full test results string single False

parameters

name code description dataType valueType required
dx/x DXVSX Fractional increase in length float single True
dy/y DYVSY Fractional increase in width float single True

test code: BTWEIGHT

stages: BARE, COCURED

properties

name code description dataType valueType required
Name of Operator OPERATOR Name of operator conducting the test string single False

parameters

name code description dataType valueType required
Weight [g] WEIGHT Weight of bus tape in grams float single True

test code: BTVISUAL

stages: BARE, COCURED

properties

name code description dataType valueType required
Name of Operator OPERATOR Name of operator conducting the test string single False

parameters

name code description dataType valueType required
Code of Inspection INSPECTIONCODE Result of visual inspection (accepted, under review, failed) string single True

test code: BTCOCURING

stages: COCURED

properties

name code description dataType valueType required
Name of Autoclave AUTOCLAVE_NAME Name/ID of the Autoclave used for the co-curing string single False
Name of Operator COC_OPERATOR Name of Operator string single True

parameters

name code description dataType valueType required
Prepreg ID PREPREGID ID of prepreg roll used for the facesheet string single True
Plate ID of Co-Curing PLATE_ID ID of the plate for the co-curing process (DESY specific) string single False

test code: BTTHICKNESS

stages: COCURED

properties

name code description dataType valueType required
Name of Operator OPERATOR Name of operator conducting the test string single False

parameters

name code description dataType valueType required
Thickness [um] THICKNESS Measured thickness of bus tape in micrometer float single True

test code: BTBOND

stages: COCURED

properties

NB required flag missing

parameters

name code description dataType valueType required
Force to break BREAKINGFORCE Force to break bond wire float single True

test code: THICKNESS_CHECK

stages: RECEPTION

properties

NB required flag missing

parameters